Home / EC to ppm

SAME READING. THE RIGHT SCALE.

EC to PPM Converter

Convert conductivity or a meter’s ppm display. See 500, 640, 650 and 700 scales together, including reading ranges.

Convert your meter reading

Check your ppm scale. The same EC gives different ppm numbers on different meter settings.

Custom meter factor

Used for the custom ppm row and custom ppm input. For the 600 scale, enter 0.60—not 600.

Numbers stay as entered when you change units. Use 0–1 billion; the upper value must not be lower than the first.

CONDUCTIVITY

1.8 mS/cm

Single reading · same temperature basis

One reading, every display scale
DisplayConverted value

PPM rows are scale-based estimates. Display rounded to 8 significant digits; calculations use unrounded values.

EC to ppm: use the meter’s multiplier

For a reading in mS/cm, multiply by the scale number. For a reading in µS/cm, use the smaller TDS factor instead:

ppm = EC (mS/cm) × scale
ppm = EC (µS/cm) × factor
EC (mS/cm) = ppm ÷ scale

For example, 1.8 mS/cm gives 900 ppm on the 500 scale or 1,260 ppm on the 700 scale. A 1.2–1.8 mS/cm interval becomes 600–900 ppm on 500 or 840–1,260 ppm on 700. These are different displays of the same conductivity, not different amounts added to the water.

One mS/cm equals 1,000 µS/cm or 1 dS/m. In the hydroponic CF convention used here, CF equals EC in mS/cm multiplied by 10.

Bluelab’s conductivity-scale guide explains 500 and 700 conversions and why a ppm meter display is not a direct chemical analysis. Hanna’s EC/TDS guidance describes the factor applied to conductivity referenced to 25 °C. Always check your own meter’s documented factor.

EC to ppm conversion chart

EC in mS/cm · ppm values are meter-display estimates
EC500640650700
0.2100128130140
0.5250320325350
1500640650700
1.2600768780840
1.57509609751,050
1.89001,1521,1701,260
21,0001,2801,3001,400
2.41,2001,5361,5601,680
31,5001,9201,9502,100

Already have a ppm reading on another scale? Convert through EC: new ppm = old ppm × new scale ÷ old scale. Thus 700 ppm on 500 becomes 980 ppm on 700. This changes the display, not the solution.

Keep the measurement basis consistent

Use a temperature-compensated reading referenced to 25 °C when required by your meter. This converter does not estimate temperature coefficients, correct a raw reading, or establish calibration. A converted range retains the same factor at both ends.

Do not use these ppm estimates as water-hardness results, drinking-water safety limits or a nutrient dosing recommendation. A hardness report expressed as CaCO₃ is a separate measurement; use the water hardness converter only for that kind of report.

EC and ppm FAQs

How do I convert EC to ppm?

When EC is in mS/cm, multiply by the meter scale: 500, 640, 650 or 700. For EC in µS/cm, multiply by 0.50, 0.64, 0.65 or 0.70 instead. These are meter-display estimates, not a chemical analysis.

How do I convert ppm back to EC?

Divide ppm by the stated scale to get mS/cm. For example, 700 ppm is 1.4 mS/cm on a 500-scale meter, but 1 mS/cm on a 700-scale meter. Without the scale, the reading is ambiguous.

What does a custom TDS factor mean?

Enter the multiplier applied to EC in µS/cm. A factor of 0.50 is the 500 scale; 0.70 is the 700 scale. This tool accepts factors from 0.01 through 2. Use the documented setting on your meter, not an assumed factor.

What if I only know the ppm number?

Check the meter manual, settings or the source of the reading. This tool cannot determine the scale from ppm alone. Its table lets you compare possibilities, but does not identify which one is correct.

Can I enter a target range?

Yes. Enter a lower and an optional upper reading in the same unit and scale. Each endpoint is converted independently using the same factor. The result is a converted interval, not a confidence interval or a recommended nutrient target.

Does this correct for temperature or measure water hardness?

No. Use a temperature-compensated reading referenced to 25 °C where your meter calls for it. This tool does not apply a temperature correction, infer water hardness, evaluate drinking-water safety or recommend a nutrient dose.

Conductivity1.8 mS/cm